Pendotech DAQ

Featuring the ability to read 14 devices, PendoTECH’s Data Acquisition System™ streamlines bioprocessing data management by collecting all sensor data to a central interface. PC software displays the data, which can be real-time trended and saved to an Excel-compatible file on a hard drive for convenient data management. The DAQ software can optionally perform calculated values such as DeltaP and trans-membrane pressure that are used for certain filtration applications. Users have the ability to enter electronic notes, which are also logged to the data file, resulting in data that is supremely organized. Available inputs on the DAQ include: 4 pressure sensors, 2 scales, 2 flow meters, 1 pH probe, 1 conductivity electrode, 1 air-in-tube detector and 3 analog inputs that are configurable to other sensors such as UV, temperature and turbidity.


The PendoTECH DAQ System enables a number of different types of process sensors and scales to be connected to one central system so the data can be all displayed and collected to one data file.

INPUTS

  • 4 pressure measurements with PendoTECH Pressure Sensors which can be re-used extensively or other pressure sensors/transducers optional pH (traditional probe) conductivity electrode
  • 2 flowmeters with pulse/freq signal (each with standard calibration entry or manual calibration wizard)
  • Air Detector ( for air or liquid detection or can be used as an alarm)
  • 2 scales (by serial RS232)
  • 2 generic analog 4-20mA inputs (configured in software for range, units of measure, and digits of precision)*
  • 1 generic analog 0-10V input (configured in software for range, units of measure, and digits of precision*
  • *The 4-20mA can be configured for our single use UV flow cell/transmitter that has an 4-20mA output or temperature or turbidity transmitter

OTHER FEATURES

  • PC software for graphical interface
  • Critical alarms on pressures, pH, conductivity, and analog inputs
  • Pre-alarm condition notifications with option to send email notifications
  • Dry contact relay alarm signal (could be used to shut off a pump)
  • Optional DeltaP or TFF calcs
  • Trending up to 8 parameters
  • All data logged to a CSV file that is opened with Excel
  • Manufactured in stainless steel enclosure
  • CE Mark

System View
System View

Trends View
Trends View

Maintenance View
Maintenance View

  • PendoTECH Single Use Pressure Sensors
  • Air Detector
  • PH Probe
  • Conductivity Electrode

  • PDKT-PCS-DAQ: PendoTECH Sensor Data Acquisition System with alarm functions for 14 sensors/devices & PC Software
  • COND1-TFF Conductivity Probe K=1 with 100ohm Pt RTD for temperature measurement, stainless steel
  • COND2-TFF Conductivity Probe K=1 with 100ohm Pt RTD for temperature measurement, epoxy
  • COND3-TFF Conductivity Glass flow cell K=1 for 1/4inch ID tubing w/100ohm Pt RTD for temperature measurement
  • COND4-TFF Conductivity Probe K=1 with 100ohm Pt RTD for temperature measurement, stainless steel with sanitary flange AD-XX: Ultrasonic air in-line detector (tubing size TBD)

Additional Products

PendoTECH Publication
Back to Top